Why a heat pump runs backwards to melt its own frost

In cold, humid air the outdoor coil ices up. Step through the cycle and watch the refrigerant reverse, the outdoor fan stop and the indoor aux heat step in.

Hot refrigerant gasCold low-pressure refrigerantFrost on the outdoor coilCutaway teaching model, not to scale. Numbers: 1 outdoor coil, 2 outdoor fan, 3 reversing valve, 4 compressor, 5 indoor coil, 6 aux heat strips, 7 defrost control board.
Coil frost0%of outdoor coil blocked
Heat pump output100%vs. a clean coil
Outdoor fanRunningValve: heating position
Aux heat stripsOffelectric resistance
Supply airWarminto the house

A simplified model

Exact control sequences vary by manufacturer. Many units start defrost from a timer plus a coil-temperature or pressure check and end it on coil temperature or a time limit; fan, valve and aux-heat timing differ. This simulation shows one generic sequence for learning. Follow the unit's own service documentation for real equipment.